Gyms & sports halls

Emergency lighting in gyms. Even when the class lights are off.

In a spin class the lights are dimmed, someone runs fast on the treadmill, a ball game is on in the hall. When the power fails, there must be no panic. We design anti-panic lighting and exit signs for studios and halls – robust and unobtrusive.

Request a free on-site survey+49 171 1935852
In short

Gyms are workplaces with public access: safety lighting follows from the risk assessment, building permit and fire safety concept. Large class rooms often need anti-panic lighting with at least 0.5 lx to EN 1838. Sports halls and rooms for more than 200 visitors may fall under places of assembly regulations. In sports halls, luminaires must be ball-impact resistant or protected.

0.5 lxanti-panic lighting in large rooms
200visitors – places of assembly rules usually apply
90°/180°adjustable light output of the escape route luminaire
Gyms & sports halls

What applies?

  • Escape route lighting and exit signs to EN 1838 and ISO 7010
  • Anti-panic lighting in large training and class rooms – even when room lighting is dimmed for classes
  • Places of assembly rules for rooms with more than 200 visitors, e.g. halls with stands
  • Ball-impact-resistant luminaires or protective guards in sports halls
  • Safety lighting at equipment with injury risk if the risk assessment calls for it
  • Self-test and logbook – testing without interrupting long opening hours

This describes typical requirements, using Germany as the reference. What applies to your building depends on the building permit, fire safety concept, risk assessment and national or regional rules – exactly what we check during the free on-site survey.

Common mistakes

Common mistakes

Class room in the dark

The lights are dimmed for classes – without anti-panic lighting the room is pitch dark in a power cut.

Signs behind equipment

New machines are placed in front of exit signs and block the route.

Hall luminaires broken

Balls hit unprotected emergency luminaires – a common defect at inspections.

NOTLUX

How we make it easy

Free on-site survey

We survey the building, escape routes and existing system and create a standard-compliant emergency lighting design – free and non-binding.

Matching Series 19 luminaires

Exit sign, escape route and recessed luminaires plus emergency drivers – with self-test and LiFePO4 battery.

Maintenance via app

Every test documented digitally, deadlines monitored automatically – ready to show at any inspection.

All-round maintenance contract

Annual on-site inspection, all batteries replaced in year 5–6 and repairs – predictable costs instead of surprises.

Frequently asked questions

Does a gym need emergency lighting?

In most cases yes: large rooms, public access, equipment with injury risk and long opening hours regularly lead to safety lighting in the risk assessment and fire safety concept.

What is anti-panic lighting?

Safety lighting for large rooms without defined escape routes. With at least 0.5 lx it prevents panic in a power cut and makes the way to the escape routes visible.

When is a sports hall a place of assembly?

When rooms are intended for more than 200 visitors, for example halls with stands or for events. The places of assembly regulations then apply.

What does ball-impact resistant mean?

Luminaires in sports halls must withstand balls without being damaged or losing parts. Options are tested ball-impact-resistant luminaires or suitable protective guards.

How does testing work with long opening hours?

Self-test luminaires test themselves at times you set – at night, for example. Results appear in the app, and we fix defects under the maintenance contract.